| control method |
Stored program iterative operation |
| Input / output control method |
Refresh method |
| Programming language |
Sequence control language |
Relay symbol word, function block |
| processing speed |
Sequence instruction |
LD X0 |
0.10µs |
| MOV D0 D1 |
0.35µs |
| Constant scan |
1-2000ms (can be set in 1ms increments) |
| Program capacity |
14K steps (56K bytes) |
| Memory capacity |
Program memory (drive 0) |
128K bytes |
| Standard ROM (drive 4) |
128K bytes |
| Maximum number of stored files |
Program memory |
3 |
| Standard ROM |
3 |
| Number of writes to standard ROM |
Up to 100,000 times |
| I / O device points |
6144 points (X / Y0-17FF) |
| Number of input / output points |
1024 points (X / Y0-3FF) |
| Device score |
Internal relay [M] |
Default 6144 points (M0-6143) (changeable) |
| Link relay [B] |
Default 2048 points (B0-7FF) (changeable) |
| Timer [T] |
Default 512 points (T0 to 511) (shared low-speed timer / high-speed timer) (can be changed) Low-speed timer / high-speed timer is specified by an instruction The measurement unit of low-speed timer / high-speed timer is set by a parameter (low-speed timer: 1 to 1000 ms, 1ms unit, default 100ms) (High-speed timer: 0.1-100.0ms, 0.1ms unit, default 10.0ms) |
| Accumulation timer [ST] |
Default 0 points (shared low-speed integration timer / high-speed integration timer) (can be changed) Low-speed integration timer / high-speed integration timer is specified by an instruction The measurement unit of low-speed integration timer / high-speed integration timer is set by a parameter (low-speed integration timer: 1 to 1 to 1000ms, 1ms unit, default 100ms) (High-speed integration timer: 0.1-100.0ms, 0.1ms unit, default 10.0ms) |
| Counter [C] |
Normal counter: Default 512 points (C0 to 511) (changeable) |
| Data register [D] |
Default 6144 points (D0-6143) (changeable) |
| Link register [W] |
Default 2048 points (W0-7FF) (changeable) |
| Ananceta [F] |
Default 1024 points (F0-1023) (changeable) |
| Edge relay [V] |
Default 1024 points (V0-1023) (changeable) |
| Link special relay [SB] |
1536 points (SB0-5FF) (device points are fixed) |
| Link special register [SW] |
1536 points (SW0-5FF) (device points are fixed) |
| Special relay [SM] |
5120 points (SM0-5119) (device points are fixed) |
| Special register [SD] |
5120 points (SD0-5119) (device points are fixed) |
| RUN / PAUSE contacts |
One RUN contact can be set from X0 to 17FF No PAUSE contact |
| Clock function |
Year, month, day, hour, minute, second, day of the week (leap year automatic discrimination) Accuracy: -3.18 to +5.25s (TYP. +2.14s) / d at 0 ° C Accuracy: -3.18 to +2.59s (TYP. +) 2.07s) / d at 25 ℃ Accuracy: -12.97 ~ + 3.63s (TYP. -3.16s) / d at 55 ℃ |
| Allowable momentary power failure time |
Depends on the power supply unit |
| DC5V internal current consumption |
0.58A |
| External dimensions |
Height (H) |
98mm |
| Width (W) |
55.2mm |
| Depth (D) |
114mm |
| mass |
0.29kg |
| Protection class |
IP2X |