企讯网企业
手机商铺
手机商铺
扫描进入手机商铺
长沙市智念自动化设备有限公司 http://www.114my.cn/shopdetail/40790/

主营:空心轴磁粉离合器,三菱LX-TD型张力检测器,三菱伺服电机,TOSHIBA东芝变频器

商铺首页 产品展示 企业简介 企业动态 招聘中心 在线留言 联系我们
未认证企业
长沙市智念自动化设备有限公司
  • 0
  • 说明
    • 会员认证:网站通过企讯网认证,真实合法,放心访问;
    • 官网认证:网站通过工信部备案,真实合法,放心访问;
    • 工商认证:企业通过工商注册,营业执照真实有效;
    • 加V认证:企业通过百度信誉认证,百度优先赔付;
    • 诚信通认证:企业在阿里巴巴诚信通有资料,已经开通阿里巴巴旺铺;
    • 微店认证:企业开通朝阳微商城,可以通过移动网络购买商品。
    • 认证或商铺装修请联系企讯网客服: 点击这里给我发消息
      电 话:158-1425-6793
  • 主 营:空心轴磁粉离合器,三菱LX-TD型张力检测器,三菱伺服电机,TOSHIBA东芝变频器

产品分类

企业动态

最新产品

手机商铺

手机查看产品信息

  • CJ1W-ID211
  • CJ1W-ID211

  • 发布时间:2021-01-14 16:27:58
  • 关键词:CJ1W-ID211,东莞CJ1W-ID211
  • 产品描述:智念自动化设备有限公司是一家专注于生产三菱PLC系列的公司_服务电话:0769-85087166
  • 留言询价
  • 详细信息
  • 联系我们

CJ1W-ID201 DC Input Unit (12 to 24-VDC, 8 Points)

Name8-point DC Input Unit with Terminal Block
ModelCJ1W-ID201
Rated Input Voltage12 to 24 VDC
Rated Input Voltage Range10.2 to 26.4 VDC
Input Impedance2.4 kΩ
Input Current10 mA typical (at 24 VDC)
ON Voltage/ON Current8.8 VDC min./3 mA min.
OFF Voltage/OFF Current3 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
Number of Circuits8 independent circuits
Number of Simultaneously
ON Points
100% simultaneously ON
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption80 mA max.
Weight110 g max.
Circuit Configuration
2054_sp_1_1
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
External connection and
terminal-device variable
diagram
2054_sp_1_2
Polarity of the input power supply can be connected in either direction.
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
*1. The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response
       time are set to 0 ms due to internal element delays.
*2. Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.
       They are not printed on the Units.
Note: Although 16 I/O bits (1 word) are allocated, only 8 of these can be used for external I/O.

CJ1W-ID211 DC Input Unit (24 VDC, 16 Points)

Name16-point DC Input Unit with Terminal Block
ModelCJ1W-ID211
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance3.3 kΩ
Input Current7 mA typical (at 24 VDC)
ON Voltage/ON Current14.4 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
Number of Circuits16 (16 points/common, 1 circuit)
Number of Simultaneously
ON Points
100% simultaneously ON (at 24 VDC) (Refer to the following illustration.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption80 mA max.
Weight110 g max.
Circuit Configuration
2054_sp_2_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_2_2
External connection and
terminal-device variable
diagram
2054_sp_2_3
Polarity of the input power supply can be connected in either direction.
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
*1. The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response
       time are set to 0 ms due to internal element delays.
*2. Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.
       They are not printed on the Units.

CJ1W-ID212 DC Input Unit (24 VDC, 16 Points)

Name16-point DC Input Unit with Terminal Block
ModelCJ1W-ID212
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance3.3 kΩ
Input Current7 mA typical (at 24 VDC)
ON Voltage/ON Current14.4 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 ms in the Setup.) *1
Number of Circuits16 (16 points/common, 1 circuit)
Number of Simultaneously
ON Points
100% simultaneously ON (at 24 VDC) (Refer to the following illustration.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption130 mA max.
Weight110 g max.
Circuit Configuration
2054_sp_3_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_3_2
External connection and
terminal-device variable
diagram
2054_sp_3_3
Polarity of the input power supply can be connected in either direction.
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
*1. The ON response time will be 15 μs maximum and OFF response time will be 90 μs maximum even if the response
       time are set to 0 ms due to internal element delays.
*2. Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.
       They are not printed on the Units.

CJ1W-ID231 DC Input Unit (24 VDC, 32 Points)

Name32-point DC Input Unit with Fujitsu Connector
ModelCJ1W-ID231
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance5.6 kΩ
Input Current4.1 mA typical (at 24 VDC)
ON Voltage/ON Current19.0 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
Number of Circuits32 (16 points/common, 2 circuits)
Number of Simultaneously
ON Points
75% (12 points/common) simultaneously ON (at 24 VDC) (Refer to the following illustration.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption90 mA max.
Weight70 g max.
AccessoriesNone
Circuit Configuration
2054_sp_4_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_4_2
External connection and
terminal-device variable
diagram
2054_sp_4_3
The input power polarity can be connected in either direction.
Be sure to wire both pins A9 and A18 (COM0), and set the same polarity for both pins.
Be sure to wire both pins B9 and B18 (COM1), and set the same polarity for both pins.
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
* The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response
    times are set to 0 ms due to internal element delays.
Note: Observe the following restrictions when connecting to a 2-wire sensor.
           • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the
               sensor (approx. 3 V).
           • Use a sensor with a minimum load current of 3 mA min.
           • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

CJ1W-ID232 DC Input Unit (24 VDC, 32 Points)

Name32-point DC Input Unit with MIL Connector
ModelCJ1W-ID232
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance5.6 kΩ
Input Current4.1 mA typical (at 24 VDC)
ON Voltage/ON Current19.0 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
Number of Circuits32 (16 points/common, 2 circuits)
Number of Simultaneously
ON Points
75% (12 points/common) simultaneously ON (at 24 VDC) (Refer to the following illustration.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption90 mA max.
Weight70 g max.
AccessoriesNone
Circuit Configuration
2054_sp_5_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_5_2
External connection and
terminal-device variable
diagram
2054_sp_5_3
The input power polarity can be connected in either direction.
Be sure to wire both pins 23 and 24 (COM0), and set the same polarity for both pins.
Be sure to wire both pins 3 and 4 (COM1), and set the same polarity for both pins.
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
* The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response
    times are set to 0 ms due to internal element delays.
Note: Observe the following restrictions when connecting to a 2-wire sensor.
          • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the
              sensor (approx. 3 V).
          • Use a sensor with a minimum load current of 3 mA min.
          • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

CJ1W-ID233 DC Input Unit (24 VDC, 32 Points)

Name32-point DC Input Unit with MIL Connector
ModelCJ1W-ID233
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance5.6 kΩ
Input Current4.1 mA typical (at 24 VDC)
ON Voltage/ON Current19.0 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
Number of Circuits32 (16 points/common, 2 circuits)
Number of Simultaneously
ON Points
75% (12 points/common) simultaneously ON (at 24 VDC) (Refer to the following illustration.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption200 mA max.
Weight70 g max.
AccessoriesNone
Circuit Configuration
2054_sp_6_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_6_2
External connection and
terminal-device variable
diagram
2054_sp_6_3
The input power polarity can be connected in either direction.
Be sure to wire both pins 23 and 24 (COM0), and set the same polarity for both pins.
Be sure to wire both pins 3 and 4 (COM1), and set the same polarity for both pins.
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
* The ON response time will be 15 μs maximum and OFF response time will be 90 μs maximum even if the response
    times are set to 0 ms due to internal element delays.
Note: Observe the following restrictions when connecting to a 2-wire sensor.
          • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the
              sensor (approx. 3 V).
          • Use a sensor with a minimum load current of 3 mA min.
          • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

CJ1W-ID261 DC Input Unit (24 VDC, 64 Points)

Name64-point DC Input Unit with Fujitsu Connector
ModelCJ1W-ID261
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance5.6 kΩ
Input Current4.1 mA typical (at 24 VDC)
ON Voltage/ON Current19.0 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
Number of Circuits64 (16 points/common, 4 circuits)
Number of Simultaneously
ON Points
50% (16 points/common) simultaneously ON (at 24 VDC) (Refer to the following illustrations.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption90 mA max.
Weight110 g max.
AccessoriesNone
Circuit Configuration
2054_sp_7_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_7_2
External connection and
terminal-device variable
diagram
CN1CN2
2054_sp_7_3
The input power polarity can be connected in either
direction.
Be sure to wire both pins A9 and A18 (COM0) of
CN1, and set the same polarity for both pins.
Be sure to wire both pins B9 and B18 (COM1) of
CN1, and set the same polarity for both pins.
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_7_4
The input power polarity can be connected in either
direction.
Be sure to wire both pins A9 and A18 (COM2) of
CN2, and set the same polarity for both pins.
Be sure to wire both pins B9 and B18 (COM3) of
CN2, and set the same polarity for both pins.
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
* The ON response time will be 120 μs maximum and OFF response time will be 400 μs maximum even if the response
    times are set to 0 ms due to internal element delays.
Note: Observe the following restrictions when connecting to a 2-wire sensor.
          • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the
              sensor (approx. 3 V).
          • Use a sensor with a minimum load current of 3 mA min.
          • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

CJ1W-ID262 DC Input Unit (24 VDC, 64 Points)

Name64-point DC Input Unit with MIL Connector
ModelCJ1W-ID262
Rated Input Voltage24 VDC
Rated Input Voltage Range20.4 to 26.4 VDC
Input Impedance5.6 kΩ
Input Current4.1 mA typical (at 24 VDC)
ON Voltage/ON Current19.0 VDC min./3 mA min.
OFF Voltage/OFF Current5 VDC max./1 mA max.
ON Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
OFF Response Time8.0 ms max. (Can be set to between 0 and 32 in the Setup.) *
Number of Circuits64 (16 points/common, 4 circuits)
Number of Simultaneously
ON Points
50% (8 points/common) simultaneously ON (at 24 VDC) (Refer to the following illustrations.)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (100 VDC)
Dielectric Strength1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption90 mA max.
Weight110 g max.
AccessoriesNone
Circuit Configuration
2054_sp_8_1
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_8_2
External connection and
terminal-device variable
diagram
CN1CN2
2054_sp_8_3
The input power polarity can be connected in
either direction.
Be sure to wire both pins 23 and 24 (COM0) of
CN1, and set the same polarity for both pins.
Be sure to wire both pins 3 and 4 (COM1) of CN1,
and set the same polarity for both pins.
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
2054_sp_8_4
The input power polarity can be connected in
either direction.
Be sure to wire both pins 23 and 24 (COM2) of
CN2, and set the same polarity for both pins.
Be sure to wire both pins 3 and 4 (COM3) of CN2,
and set the same polarity for both pins.
The signal names of the terminals are the device
variable names.
The device variable names are the names that use
"Jxx" as the device name.
* The ON response time will be 120 μs maximum and OFF response time will be 400 μs maximum even if the response
    times are set to 0 ms due to internal element delays.
Note: Observe the following restrictions when connecting to a 2-wire sensor.
          • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the
              sensor (approx. 3 V).
          • Use a sensor with a minimum load current of 3 mA min.
          • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

CJ1W-IA201 AC Input Unit (200 VAC, 8 Points)

Name8-point AC Input Unit with Terminal Block
ModelCJ1W-IA201
Rated Input Voltage200 to 240 VAC 50/60 Hz
Rated Input Voltage Range170 to 264 VAC
Input Impedance21 kΩ (50 Hz), 18 kΩ (60 Hz)
Input Current9 mA typical (at 200 VAC, 50 Hz), 11 mA typical (at 200 VAC, 60 Hz)
ON Voltage/ON Current120 VAC min./4 mA min.
OFF Voltage/OFF Current40 VAC max./2 mA max.
ON Response Time18.0 ms max. (default setting: 8 ms) *1
OFF Response Time48.0 ms max. (default setting: 8 ms) *1
Number of Circuits8 (8 points/common, 1 circuit)
Number of Simultaneously
ON Points
100% (8 points/common) simultaneously ON
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (500 VDC)
Dielectric Strength2,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption80 mA max.
Weight130 g max.
AccessoriesNone
Circuit Configuration
2054_sp_9_1
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
External connection and
terminal-device variable
diagram
2054_sp_9_2
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
*1. Can be set to 0 ms, 0.5 ms, 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, or 32 ms in the settings. When the response times have
       been set to 0 ms, the ON response time will be 10 ms maximum and the OFF response time will be 55 ms maximum
       due to internal element delays.
*2. Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.
       They are not printed on the Units.
Note: Although 16 I/O bits (1 word) are allocated, only 8 of these can be used for external I/O.

CJ1W-IA111 AC Input Unit (100 VAC, 16 points)

Name16-point AC Input Unit with Terminal Block
ModelCJ1W-IA111
Rated input voltage100 to 120 VAC 50/60 Hz *2
Rated Input Voltage Range85 to 132 VAC
Input Impedance14.5 kΩ (50 Hz), 12 kΩ (60 Hz)
Input Current7 mA typical (at 100 VAC, 50 Hz), 8 mA typical (at 100 VAC, 60 Hz)
ON Voltage/ON Current70 VAC min./4 mA min
OFF Voltage/OFF Current20 VAC max./2 mA max
ON Response Time18 ms max. (default setting: 8 ms) *1
OFF Response Time48 ms max. (default setting: 8 ms) *1
Number of Circuits16 (16 points/common, 1 circuit)
Number of Inputs ON
Simultaneously
100% simultaneously ON (16 points/common)
Insulation Resistance20 MΩ min. between external terminals and the GR terminal (500 VDC)
Dielectric Strength2,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of
10 mA max.
Internal Current Consumption90 mA max.
Weight130 g max.
AccessoriesNone
Circuit Layout
2054_sp_10_1
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
External connection and
terminal-device variable
diagram
2054_sp_10_2
The signal names of the terminals are the device variable names.
The device variable names are the names that use "Jxx" as the device name.
*1. Can be set to 0 ms, 0.5 ms, 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, or 32 ms in the settings. When the response times have
       been set to 0 ms, the ON response time will be 10 ms maximum and the OFF response time will be 55 ms maximum
       due to internal element delays.
*2. Use an input voltage of 90 VAC or higher when connecting 2-wire sensors.
*3. Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.
       They are not printed on the Units.

Bit Allocations for Input Unit

8-point Input Unit

Allocated CIO wordSignal name (CJ/NJ)
CIOBit
Wd m
(Input)
00IN0/Jxx_Ch1_In00
01IN1/Jxx_Ch1_In01
::
06IN6/Jxx_Ch1_In06
07IN7/Jxx_Ch1_In07
08-
09-
::
14-
15-

16-point Input Unit

Allocated CIO wordSignal name (CJ/NJ)
CIOBit
Wd m
(Input)
00IN0/Jxx_Ch1_In00
01IN1/Jxx_Ch1_In01
::
14IN14/Jxx_Ch1_In14
15IN15/Jxx_Ch1_In15

32-point Input Unit

Allocated CIO wordSignal name (CJ/NJ)
CIOBit
Wd m
(Input)
00IN0/Jxx_Ch1_In00
01IN1/Jxx_Ch1_In01
::
14IN14/Jxx_Ch1_In14
15IN15/Jxx_Ch1_In15
Wd m+1
(Input)
00IN0/Jxx_Ch2_In00
01IN1/Jxx_Ch2_In01
::
14IN14/Jxx_Ch2_In14
15IN15/Jxx_Ch2_In15

64-point Input Unit

Allocated CIO wordSignal name (CJ/NJ)
CIOBit
Wd m
(Input)
00IN0/Jxx_Ch1_In00
01IN1/Jxx_Ch1_In01
::
14IN14/Jxx_Ch1_In14
15IN15/Jxx_Ch1_In15
Wd m+1
(Input)
00IN0/Jxx_Ch2_In00
01IN1/Jxx_Ch2_In01
::
14IN14/Jxx_Ch2_In14
15IN15/Jxx_Ch2_In15
Wd m+2
(Input)
00IN0/Jxx_Ch3_In00
01IN1/Jxx_Ch3_In01
::
14IN14/Jxx_Ch3_In14
15IN15/Jxx_Ch3_In15
Wd m+3
(Input)
00IN0/Jxx_Ch4_In00
01IN1/Jxx_Ch4_In01
::
14IN14/Jxx_Ch4_In14
15IN15/Jxx_Ch4_In15


长沙市智念自动化设备有限公司
  • 联系人:贺小姐女士
  • 手 机:13825757614
  • 电 话:0769-85087166
  • 传 真:0769-85087166
  • 地 址:广东省东莞市厚街镇康乐南路新塘泽美大厦608室
  • 主 营:空心轴磁粉离合器,三菱LX-TD型张力检测器,三菱伺服电机,TOSHIBA东芝变频器

长沙市智念自动化设备有限公司 地址:广东省 东莞市 厚街镇康乐南路新塘泽美大厦608室 技术支持:商铺管理入口 | 产品索引 | 免责声明